Onboard wiring design effectively reduces stray inductance and improves system anti-interference capability; power redundancy design of the power supply unit ensures power supply reliability. The drive uses unique speed recognition technology combined with drive output phase detection technology to quickly track the motor rotation voltage-frequency curve and quickly increase the operating frequency to the set speed.
Product Summary

Specifications
|
Parametric |
|
|
Model |
RVE1000S-6/280 ~ RVE1000S-6/560 |
|
Voltage |
6kV |
|
VFD power (kW) |
280/315/355/400/450/500/560 |
|
Output current (A) |
34/38/43/48/54/61/67 |
|
Capacity (kVA) |
350/400/450/500/560/630/700 |
|
External dimensions (excluding fan assembly) W'D*H mm |
1600*1330*2000 |
Technical Specifications
|
Input Power |
|
|
Input line voltage |
3.0~35kV(-10%~+10%) |
|
Input voltage fluctuation |
-35%~+15%rated voltage |
|
Input voltage frequency |
50/60Hz±5% |
|
Input power factor |
It can reach over 0.95 when the load exceeds 20%. |
|
Control power |
Three-phase four-wire system, 380V, 5~50kVA (depending on inverter capacity). |
|
Output Power |
|
|
Output line voltage |
0~11 kV |
|
Output frequency |
0~120Hz |
|
Output frequency drift |
±0.5% |
|
Output efficiency |
≧96% |
|
Output frequency resolution |
0.01Hz |
|
Control function |
|
|
Speed range |
0.01~120Hz (motor-dependent) |
|
Overload |
120%, 60s (customizable) |
|
Control method |
VF control/GVC control/torque control/vector control |
|
control precision |
±0.5% |
|
Load torque characteristics |
Square torque load, constant torque load |
|
Acc/ Dec time |
0~3200S (adjustable according to load characteristics) |
|
Main protect function |
Overvoltage, overcurrent, short circuit, overheating, fiber optic communication, unit, etc. |
|
Input & Output capabilities |
|
|
Digital input |
24 digital inputs, expandable to 46 |
|
Digital output |
16 digital outputs, expandable to 40 |
|
Analog input |
2 analog inputs (0~10V/4~20mA) |
|
Analog output |
2 analog outputs (0~10V/4~20mA) |
|
Communication |
Standard: Modbus; Optional: Profibus-DP, Profinet, TCP/IP, etc. |
|
Display |
|
|
User Interface |
Touchscreen |
|
Transformer characteristics |
|
|
Temperature protection |
130℃ fault |
|
Insulation level |
H |
|
Environmental conditions |
|
|
Protection Rating |
IP30 |
|
Cooling Method |
Forced air cooling |
|
Maintenance Method |
Front and back of VFD maintenance |
|
Operating Ambient Temperature |
0~+40℃ |
|
Storage and Transportation Temperature |
-20℃~+70℃ |
|
Humidity |
<95%, non-condensing |
|
Vibration |
Below 0.9g |
|
Usage Location |
Indoor environment free from corrosive, explosive gases, and dust |
|
Usage Altitude |
Altitude 2000 meters and below |
Power Unit Topology

Model Nomenclature

Product Selection Table
|
Rated Output Voltage (kV) |
Inverter Model |
Rated Output Current (A) |
Compatible Motor Power (kW) |
Transformer Capacity (kVA) |
Dimensions (excluding fan assembly) W*D*H mm |
|
6KV |
RV1000S-6/280 |
34 |
280 |
350 |
1600*1330*2000 |
|
RV1000S-6/315 |
38 |
315 |
400 |
1600*1330*2000 |
|
|
RV1000S-6/355 |
43 |
355 |
450 |
1600*1330*2000 |
|
|
RV1000S-6/400 |
48 |
400 |
500 |
1600*1330*2000 |
|
|
RV1000S-6/450 |
54 |
450 |
560 |
1600*1330*2000 |
|
|
RV1000S-6/500 |
61 |
500 |
630 |
1600*1330*2000 |
|
|
RV1000S-6/560 |
67 |
560 |
700 |
1600*1330*2000 |
|
|
10KV |
RV1000S-10/280 |
20 |
280 |
350 |
1600*1330*2000 |
|
RV1000S-10/315 |
23 |
315 |
400 |
1600*1330*2000 |
|
|
RV1000S-10/355 |
26 |
355 |
450 |
1600*1330*2000 |
|
|
RV1000S-10/400 |
29 |
400 |
500 |
1600*1330*2000 |
|
|
RV1000S-10/450 |
32 |
450 |
560 |
1600*1330*2000 |
|
|
RV1000S-10/500 |
36 |
500 |
630 |
1600*1330*2000 |
|
|
RV1000S-10/560 |
40 |
560 |
700 |
1600*1330*2000 |
|
|
RV1000S-10/630 |
46 |
630 |
800 |
1600*1330*2000 |
|
|
RV1000S-10/710 |
52 |
710 |
900 |
1600*1330*2000 |
|
|
RV1000S-10/800 |
58 |
800 |
1000 |
1600*1330*2000 |
|
|
RV1000S-10/900 |
65 |
900 |
1120 |
1600*1330*2000 |
|
|
RV1000S-10/1000 |
72 |
1000 |
1250 |
1600*1330*2000 |

English
Español
عربى