Product Summary

Specifications
|
Parametric |
|
|
Model |
RVE1000S-6/280 ~ RVE1000S-6/560 |
|
Voltage |
6kV |
|
VFD power (kW) |
280/315/355/400/450/500/560 |
|
Output current (A) |
34/38/43/48/54/61/67 |
|
Capacity (kVA) |
350/400/450/500/560/630/700 |
|
External dimensions (excluding fan assembly) W'D*H mm |
1600*1330*2000 |
Technical Specifications
|
Input Power |
|
|
Input line voltage |
3.0~35kV(-10%~+10%) |
|
Input voltage fluctuation |
-35%~+15%rated voltage |
|
Input voltage frequency |
50/60Hz±5% |
|
Input power factor |
It can reach over 0.95 when the load exceeds 20%. |
|
Control power |
Three-phase four-wire system, 380V, 5~50kVA (depending on inverter capacity). |
|
Output Power |
|
|
Output line voltage |
0~11 kV |
|
Output frequency |
0~120Hz |
|
Output frequency drift |
±0.5% |
|
Output efficiency |
≧96% |
|
Output frequency resolution |
0.01Hz |
|
Control function |
|
|
Speed range |
0.01~120Hz (motor-dependent) |
|
Overload |
120%, 60s (customizable) |
|
Control method |
VF control/GVC control/torque control/vector control |
|
control precision |
±0.5% |
|
Load torque characteristics |
Square torque load, constant torque load |
|
Acc/ Dec time |
0~3200S (adjustable according to load characteristics) |
|
Main protect function |
Overvoltage, overcurrent, short circuit, overheating, fiber optic communication, unit, etc. |
|
Input & Output capabilities |
|
|
Digital input |
24 digital inputs, expandable to 46 |
|
Digital output |
16 digital outputs, expandable to 40 |
|
Analog input |
2 analog inputs (0~10V/4~20mA) |
|
Analog output |
2 analog outputs (0~10V/4~20mA) |
|
Communication |
Standard: Modbus; Optional: Profibus-DP, Profinet, TCP/IP, etc. |
|
Display |
|
|
User Interface |
Touchscreen |
|
Transformer characteristics |
|
|
Temperature protection |
130℃ fault |
|
Insulation level |
H |
|
Environmental conditions |
|
|
Protection Rating |
IP30 |
|
Cooling Method |
Forced air cooling |
|
Maintenance Method |
Front and back of VFD maintenance |
|
Operating Ambient Temperature |
0~+40℃ |
|
Storage and Transportation Temperature |
-20℃~+70℃ |
|
Humidity |
<95%, non-condensing |
|
Vibration |
Below 0.9g |
|
Usage Location |
Indoor environment free from corrosive, explosive gases, and dust |
|
Usage Altitude |
Altitude 2000 meters and below |
Power Unit Topology

Model Nomenclature

Product Selection Table
|
Rated Output Voltage (kV) |
Inverter Model |
Rated Output Current (A) |
Compatible Motor Power (kW) |
Transformer Capacity (kVA) |
Dimensions (excluding fan assembly) W*D*H mm |
|
6KV |
RV1000S-6/280 |
34 |
280 |
350 |
1600*1330*2000 |
|
RV1000S-6/315 |
38 |
315 |
400 |
1600*1330*2000 |
|
|
RV1000S-6/355 |
43 |
355 |
450 |
1600*1330*2000 |
|
|
RV1000S-6/400 |
48 |
400 |
500 |
1600*1330*2000 |
|
|
RV1000S-6/450 |
54 |
450 |
560 |
1600*1330*2000 |
|
|
RV1000S-6/500 |
61 |
500 |
630 |
1600*1330*2000 |
|
|
RV1000S-6/560 |
67 |
560 |
700 |
1600*1330*2000 |
|
|
10KV |
RV1000S-10/280 |
20 |
280 |
350 |
1600*1330*2000 |
|
RV1000S-10/315 |
23 |
315 |
400 |
1600*1330*2000 |
|
|
RV1000S-10/355 |
26 |
355 |
450 |
1600*1330*2000 |
|
|
RV1000S-10/400 |
29 |
400 |
500 |
1600*1330*2000 |
|
|
RV1000S-10/450 |
32 |
450 |
560 |
1600*1330*2000 |
|
|
RV1000S-10/500 |
36 |
500 |
630 |
1600*1330*2000 |
|
|
RV1000S-10/560 |
40 |
560 |
700 |
1600*1330*2000 |
|
|
RV1000S-10/630 |
46 |
630 |
800 |
1600*1330*2000 |
|
|
RV1000S-10/710 |
52 |
710 |
900 |
1600*1330*2000 |
|
|
RV1000S-10/800 |
58 |
800 |
1000 |
1600*1330*2000 |
|
|
RV1000S-10/900 |
65 |
900 |
1120 |
1600*1330*2000 |
|
|
RV1000S-10/1000 |
72 |
1000 |
1250 |
1600*1330*2000 |

English
Español
عربى