X series PLC is a powerful motion control functional PLC independently developed and designed. Including X1 economic PLC, X2 standard PLC, X3 enhanced PLC, X5 motion control PLC, X6 bus PLC, X relay PLC and expansion module, BD board. The X series PLC integrates the needs of the industry, responds to the individual needs of customers, enhances the advantages of expansion capabilities, and is the choice for control systems such as OEM equipment, small projects, and Internet of Things smart devices.
X2 series summary

With linear interpolation, two-axis high-speed pulse output high-speed counting and other motion control function;
Real-time clock, power outage data is permanently stored;
It supports a BD expansion board and can expand up to 7modules.
Advantage

X2 series parameter
|
Item |
Power Specification |
|||
|
X2-24TD |
X2-32TD |
X2-40TD |
X2-60TD |
|
|
Power consumption |
10W |
12W |
12W |
14W |
|
Power Voltage |
DC24V |
|||
|
Voltage range |
DC 20.4~28.8V |
|||
|
Allow instantaneous power outage time |
For transient power outages below 5ms, the operation will continue |
|||
|
Power fuse |
60V 2A |
|||
|
Impulse current |
12A, 0.5ms below/28.8V DC |
|||
|
DC24V given power |
300mA below |
|||
|
DC5V build-in power |
800mA below |
|||
|
Item |
Input Specification |
||||
|
X2-24TD |
X2-32TD |
X2-40TD |
X2-60TD |
||
|
Input number |
14 |
16 |
24 |
36 |
|
|
High-speed counter |
Single phase 200KHz[3 pcs], AB phase 100KHz[3 pcs] |
||||
|
Input type |
Sink type/source type |
||||
|
Input signal voltage |
DC source type: DC20.4V~28.8V |
||||
|
Input impedance |
X0-X5 |
3.3K |
|||
|
X6-X7 |
5.6K |
3.3K |
|||
|
X10 above |
- |
5.6K |
|||
|
ON input inductance current |
X0-X5 |
5mA above |
|||
|
X6-X7 |
4mA |
5mA above |
|||
|
X10 above |
- |
4mA above |
|||
|
OFF Input induced current |
1mA above |
||||
|
Input response time |
<4.5ms |
||||
|
Input signal form |
No voltage contact input |
||||
|
Sink input: NPN open-collector transistor |
|||||
|
Source input: PNP open-collector transistor |
|||||
|
Input loop isolation |
Optocoupler isolation |
||||
|
Display of input actions |
The LED on the panel lights up when the optocoupler is driven |
||||
|
Item |
Power Specification |
||||
|
X2-24TD |
X2-32TD |
X2-40TD |
X2-60TD |
||
|
Output number |
10 |
16 |
16 |
24 |
|
|
Pulse frequency( Max) |
Single-ended 2-axis 200K |
||||
|
Output type |
Transistor/Leaky output |
||||
|
External power supply |
DC5~30V |
||||
|
Max load |
Resistive load |
0.5A/way |
|||
|
Inductive load |
12W/DC24V |
||||
|
Lamp load |
5W/DC24V |
||||
|
Mid load |
5mA(DC5~24V) |
||||
|
Response |
OFF→ON |
High speed: 5μs below/10mA above(DC5~24V) |
|||
|
Common: 0.2ms below/200mAabove(DC24V) |
|||||
|
ON→OFF |
High speed: 5μs below/10mA above(DC5~24V) |
||||
|
Common: 0.2ms below/200mAabove(DC24V) |
|||||
|
Loop isolation |
Optocoupler isolation |
||||
|
Display of output actions |
The LED on the panel lights up when the optocoupler is driven |
||||
X2 series: software component resources
|
Item |
Conten |
|
|
Input relay X |
256 point |
X0~×377 |
|
Output relay Y |
256 point |
Y0~Y377 |
|
Auxiliary relay M |
7680 point |
M0~Latch start(Set the power off non-hold area) |
|
Latch start~latch end (Set power hold area, Max M1023) |
||
|
Latch End~M7679(Fixed power hold area) |
||
|
Special auxiliary relay SM |
512 point |
SM8000~SM8511 |
|
Status relay S |
4096 point |
S0~S4095 |
|
timer T |
200 point |
T0~T199(100ms Time base) |
|
T192~T199(Subroutine specialization) |
||
|
46 point |
T200~T245(10ms time base) |
|
|
4 point |
T246~T249(1ms Cumulative type) |
|
|
6 point |
T250~T255(100ms Cumulative type) |
|
|
256 point |
T256~T511(1ms time base) |
|
|
Counter 16-bit |
200 point |
C0~C199 |
|
Counter 32-bit |
56 point |
C200~C234 |
|
High Speed counter |
- |
C235~C255 |
|
Data register D |
8000 point |
D0~D7999 |
|
Special data register SD |
512 point |
SD8000~SD8511 |
|
Index register |
16 point |
V0~V7, Z0~Z7 |
|
Expansion register |
32768 point |
R0~R32767 |
|
Pointer |
4096 point |
P0~P4095 |
|
Interrupted |
6 point |
100*~150*Input interrupt |
|
3 point |
16**~18**Timing interrupt |
|
|
6 point |
1010~1060 High-speed counter interrupt |
|
|
Master control with nesting |
8 point |
NO~N7 |
|
constant K |
- |
16 bit range: -32768~+32767, 32 bit range: -2147483648~+2147483647 |
|
constant H |
- |
16 bit range: 0~FFFF, 32 bit range: 0~FFFFFFFF |
|
Real number(E) |
- |
-3.40×10-8~-1.17×1038, 1.17x10-⁸~3.40×10³8 |
|
Character string |
- |
The maximum length of a half-corner character framed by""is 32 characters |
X2 series high-speed counter
|
Distribution Input |
Single-phase single counter |
Single-phase double counter |
AB Phase counter |
|||||||||||||
|
C235 |
C236 |
C237 |
C238 |
C239 |
C240 |
C243 |
C244 |
C246 |
C247 |
C248 |
C249 |
C251 |
C252 |
C253 |
C254 |
|
|
XO |
U/D |
U/D |
U |
U |
A |
A |
||||||||||
|
X1 |
U/D |
R |
D |
D |
B |
B |
||||||||||
|
X2 |
U/D |
U/D |
U |
R |
R |
A |
||||||||||
|
X3 |
U/D |
R |
D |
S |
B |
|||||||||||
|
X5 |
U/D |
S |
U |
A |
||||||||||||
|
X6 |
U/D |
D |
B |
|||||||||||||
X2 series size

|
PLC model |
L |
|
X2-24TD-E0 |
132 |
|
X2-32TD-E0 |
150 |
|
X2-40TD-E0 |
165 |
|
X2-60TD-E0 |
210 |
X2 series wire drawing